RENDER COLOURING TOOL

MATERIALS CALCULATOR

0113 3455170

AG T29 Gypsum plaster applied by hand

For manual application of gypsum, single coat plaster on walls and ceilings in rooms not exposed to permanent moisture and condensation of steam. Provides an ideal underlay for ceramic lining, decorative plaster, finish coat, wallpaper and paint. Minimum plaster coating thickness: 8 mm. Intended for interior use.

 

 

Package
25 kg bag

£21.60

Substrate type
Walls of brick, ceramic and silicate blocks, cellular concrete blocks, walls and ceilings of concrete or prefabricated concrete components. Old, not weathered cement-lime plaster.

Substrate preparation
The surface must be clean, sound, dry and free from dust and greasy spots. Patch any defects and irregularities with ALPOL AG T29 gypsum plaster applied by hand no later than an hour before plastering. Surfaces exposed to scratching, e.g. adjacent structural material, hole corners etc., should be strengthened with 10 mm fibre-glass reinforcing mesh, embedded in the gypsum plaster. Strengthen loose surfaces with ALPOL AG 700 deep-penetrating primer. At least 24 hours prior to the application, prime concrete surfaces with ALPOL AG 702, and highly absorbing surfaces with ALPOL AG 703. Protect all steel components (frames, conduits, barriers etc.) from direct contact with gypsum, due to its corrosive action.

Instructions for use
Mix the gypsum plaster with a specified amount of clean, cold water and stir with a slow-speed mixer to reach a homogeneous mixture of required consistency. Apply the plaster uniformly onto the wall with a trowel or wide float. Upon application, distribute the plaster with an H-profile level. After the plaster initially sets (around 50 minutes), level the plaster surface with a T-profile level. Wait another 30 minutes to smoothen the plaster using a wide scraper held perpendicularly to the wall plane. Before the setting is complete, after around 20 minutes, sprinkle the plaster with water and float it with a sponge float to extract bleeding water out of the surface. After 20 minutes, smoothen the surface using a wide scraper to obtain the final smooth finish. If, during the operation, there is not enough bleeding water, moisten the plaster with water. Optimum workability of the plaster is 120 minutes. Surfaces to be covered with tiles should be left rough after scraping ā€“ no further smoothening or ā€œspongingā€ is required. To obtain a thicker coat, apply several wet-on-wet layers of plaster.

Tools
Low-speed electric mixer, floats and levels, trowel, spirit level, sponge, wide scraper, mortar container.

Working conditions
Work in ambient temperatures between +5Ā°C and +25Ā°C. Do not use additives. Protect fresh plasterwork from excessive drying and moisture. Use clean containers and tools for each mixing.

Storage
Store in original, unopened packages in dry place ā€“ shelf lifeĀ 3 months from production date. Protect from moisture during transport and storage.

Notes
The specifications and instructions of use are given for the temperature (20Ā±2)Ā°C and relative humidity of air (65Ā±5)%. The workability may alter in different conditions. Appropriate eye, respiratory system and skin protection measures should be used. Becomes alkaline after adding water. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Keep away from children. Clean fresh stains with water. The manufacturer accepts no responsibility for damage caused by unskilful or inappropriate use of the product.

General recommendations
Work according to building practice, observing health & safety standards and regulations.

Specifications
Composition: blend of gypsum binder, minerals and additives
Bulk density approx. 0,9 kg/dmĀ³
Appropriate amount of water approx. 13,5 dmĀ³/25 kg
approx. 0,54 dmĀ³/1 kg
Initial set >20 min.
Workability approx. 30 min.
Processing time approx. 120 min.
Binder content expressed in CaSO4 ā‰„50 % of the compound
Compressive strength ā‰„2 MPa
Bending strength ā‰„1 MPa
Adhesion ā‰„0,3 MPa
Fire resistance class A1
Yield approx. 27 dmĀ³ out of 25 kg
approx. 1,1 dmĀ³ out of 1 kg
Coverage approx. 0,9 kg/mĀ²/mm

Description

For manual application of gypsum, single coat plaster on walls and ceilings in rooms not exposed to permanent moisture and condensation of steam. Provides an ideal underlay for ceramic lining, decorative plaster, finish coat, wallpaper and paint. Minimum plaster coating thickness: 8 mm. Intended for interior use.

 

 